Refine your search:     
Report No.
 - 
Search Results: Records 1-2 displayed on this page of 2
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Neutron irradiation effect of high-density MoO$$_{3}$$ pellets for Mo-99 production, 2

Nishikata, Kaori; Ishida, Takuya; Yonekawa, Minoru; Kato, Yoshiaki; Kurosawa, Makoto; Kimura, Akihiro; Matsui, Yoshinori; Tsuchiya, Kunihiko; Sano, Tadafumi*; Fujihara, Yasuyuki*; et al.

KURRI Progress Report 2014, P. 109, 2015/07

As one of effective applications of the Japan Materials Testing Reactor (JMTR), JAEA has a plan to produce $$^{99}$$Mo by (n,$$gamma$$) method ((n,$$gamma$$)$$^{99}$$Mo production), a parent nuclide of $$^{99m}$$Tc. In this study, preliminary irradiation test was carried out with the high-density molybdenum trioxide (MoO$$_{3}$$) pellets in the hydraulic conveyer (HYD) of the Kyoto University Research Reactor (KUR) and the $$^{99m}$$Tc solution extracted from $$^{99}$$Mo was evaluated. After the irradiation test of the high-density MoO$$_{3}$$ pellets in the KUR, $$^{99m}$$Tc was extracted from the Mo solution and the recovery rate of $$^{99m}$$Tc achieved the target values. The $$^{99m}$$Tc solution also got the value that satisfied the standard value for $$^{99m}$$Tc radiopharmaceutical products by the solvent extraction method.

Journal Articles

Development of in-reactor observation system using Cherenkov light(VI)

Takeuchi, Tomoaki; Yamamoto, Keiichi; Otsuka, Noriaki; Shibata, Hiroshi; Shibata, Akira; Takemoto, Noriyuki; Tsuchiya, Kunihiko; Sano, Tadafumi*; Unesaki, Hironobu*; Fujihara, Yasuyuki*; et al.

KURRI Progress Report 2014, P. 108, 2015/07

Investigation of a relation between output power and brightness of Cherenkov light of a specific fuel element at KUR by a CCD camera was performed due to a development of a real-time in-core measurement technique using Cherenkov light. The results indicate that the inhomogeneous distribution of output power and the shadow of the control-rod guide tubes and the other irradiation equipment have significant effects on the brightness of the Cherenkov light. These effects could be suppressed by using a number of cameras located at various positions.

2 (Records 1-2 displayed on this page)
  • 1